Life at high temperature |
per MIL-STD-202G Method 108A
|
Operation : 1.000 hrs @ +105°C case Storage : 1.000 hrs @ +125°C ambient
|
Low temperature |
per MIL-STD-810E Method 502.3 |
Storage : 1.000 hrs @ -55°C ambient
|
Temperature cycling |
per MIL-STD-202A Method 102A |
Number of cycles : 200 Temperature change : -40°C / +85°C Transfert time : 40 min. / steady state time : 20 min. |
Thermal shock |
per MIL-STD-202G Method 107G |
Number of shocks : 100 Temperature : -55°C to + 105°C Transfer time : < 10 s / steady state time : 30 min. |
Altitude |
per MIL-STD-810E Method 500.3 |
40.000 ft, unit functionning 1.000 ft/min to 70.000 ft, unit functionning |
Humidity cyclic |
per MIL-STD-810E Method 507.3 |
Damp heat : 60 % to 88 % relative humidity Cycle 1 (31°C to 41°C) : 240 hrs |
Humidity steady state |
per MIL-STD-202G Method 103B |
Damp heat : 93 % relative humidity Temperature : 40°C Duration : 56 days
|
Salt atmosphere |
per MIL-STD-810E Method 509.1 |
Temperature : 35°C Duration : 48 hrs |
Vibration |
per MIL-STD-810D Method 514.3 |
10 cycles in each axis Frequency : 10 to 60Hz/60Hz to 2kHz Amplitude/acceleration : 0,7 mm/10 g |
Shock |
per MIL-STD-810D Method 516.3 |
3 shocks in each axis Peak acceleration : 100 g Duration : 6 ms |
Bumps |
per MIL-STD-810D Method 516.3 |
2.000 bumps in each directions Duration : 6 ms Peak acceleration : 40 g |
Conducted emission |
per MIL-STD-461C CE01 Fig 2.1 CE03 Fig 2.2 |
module stand alone with externel filter (see technical datasheet for details) |
Conducted Susceptibility |
per MIL-STD-461C CS01, CS02, CS06
|
with external filter (see technical datasheet for details) |
Radiated emission |
per MIL-STD-461C RE01, RE02 |
module stand alone |
Radiated susceptibility |
per MIL-STD-461C RS01, RS03 |
module stand alone |