Compact Pressure Switches
6900 Series- Standard Switch Features
Pressure Series: 6900G, 6900GZ, 6900P - Wide Range DiaphragmPiston.
Pressure 1 to 6500 psi.
Standard Features:• NEMA 4, 13 • Weatherproof, • 6900 only—CSA Certified enclosure 4 non-hazardous locations File LR22665 ,
Ambient Temp. Range:-30°F to +160°F or -34°C to +71°C.
Pressure Series: 6901G, 6901GZ, 6901P - Wide Range DiaphragmPiston.
Pressure 1 to 6500 psi.
Standard Features:• NEMA 4, 13 • Weatherproof, • 6900 only—CSA Certified enclosure 4 non-hazardous locations File LR22665 ,
Ambient Temp. Range:-30°F to +160°F or -34°C to +71°C.
Pressure Series: 6900GE6900PE - Wide Range DiaphragmPiston.
Pressure 1 to 6500 psi.
Standard Features:•U.L./CSA Explosion Proof: Div. 1, 2. Div. 1 explosion-proofhermetically sealed electrical assembly P/N 46-1058 46-1061 for "M" model option, listed by both Underwriter’s Laboratories, Inc. File No. E32961CSA Testing Laboratories File No. 22921 for hazardous locations, Class 1, Groups A, B, C,D; Class 2 Groups E, F,G. •NEMA 4, 7, 9, 13.
Ambient Temp. Range:-30°F to +160°F or -34°C to +71°C.
Pressure Series: 6900GZE6900GZE-7042 - Wide Range Diaphragm, SST PortSST Construction.
Pressure 1 to 2500 psi.
Standard Features:•U.L./CSA Explosion Proof: Div. 1, 2. Div. 1 explosion-proofhermetically sealed electrical assembly P/N 46-1058 46-1061 for "M" model option, listed by both Underwriter’s Laboratories, Inc. File No. E32961CSA Testing Laboratories File No. 22921 for hazardous locations, Class 1, Groups A, B, C,D; Class 2 Groups E, F,G. •NEMA 4, 7, 9, 13.
Ambient Temp. Range:-30°F to +160°F or -34°C to +71°C.
Pressure Series: 6900GZE*-70666900GZE*-7074 - Wide Range DiaphragmFlush Mount.
Pressure 1 to 2500 psi.
Standard Features:•U.L./CSA Explosion Proof: Div. 1, 2. Div. 1 explosion-proofhermetically sealed electrical assembly P/N 46-1058 46-1061 for "M" model option, listed by both Underwriter’s Laboratories, Inc. File No. E32961CSA Testing Laboratories File No. 22921 for hazardous locations, Class 1, Groups A, B, C,D; Class 2 Groups E, F,G. •NEMA 4, 7, 9, 13.
Ambient Temp. Range:-30°F to +160°F or -34°C to +71°C.
Pressure Series: 6900DZE - Low/Mid Range Diaphragm SST Port.
Differential Pressure 0.4 to 75 psid.
Standard Features:•U.L./CSA Explosion Proof: Div. 1, 2. Div. 1 explosion-proofhermetically sealed electrical assembly P/N 46-1058 46-1061 for "M" model option, listed by both Underwriter’s Laboratories, Inc. File No. E32961CSA Testing Laboratories File No. 22921 for hazardous locations, Class 1, Groups A, B, C,D; Class 2 Groups E, F,G. •NEMA 4, 7, 9, 13.
Ambient Temp. Range:-30°F to +160°F or -34°C to +71°C.
Pressure Series: 611G, 611GE611V, 611VE - Low Range Diaphragm.
Pressure 0.75 to 180 psi. and Vacuum 1.5 to 28.5" Hg.
Standard Features:• Model 611GE —U.L./CSA Explosion Proof: Div. 1, 2 Div. 1 explosion-proofhermetically sealed electrical assembly P/N 46-1058 46-1061 for "M" model option, listed by both Underwriter’s Laboratories, Inc. File No. E32961CSA Testing Laboratories File No. 22921 for hazardous locations, Class 1, Groups A, B, C,D; Class 2 Groups E, F,G. • NEMA 4, 7, 9, 13. • Weatherproof.
Ambient Temp. Range:-30°F to +160°F or -34°C to +71°C.
Pressure Series: 611GZE*8100 - Low Range DiaphragmSST Construction
Pressure 1 to 180 psi.
Standard Features:• U.L./CSA Explosion Proof: Div. 1, 2 Div. 1 explosion-proofhermetically sealed electrical assembly P/N 46-1058 46-1061 for "M" model option, listed by both Underwriter’s Laboratories, Inc. File No. E32961CSA Testing Laboratories File No. 22921 for hazardous locations, Class 1, Groups A, B, C,D; Class 2 Groups E, F,G. • NEMA 4, 7, 9, 13. • Weatherproof.
Ambient Temp. Range:-30°F to +160°F or -34°C to +71°C.
Standard Pressure Switches
Pressure Series: 6810G, 6812G - Low Range Diaphragm/Instrumentation
Pressure 1.5 H2O to 100 psi.
Model 6810G - Stripped with Single SettingModel 6812G - Stripped with Dual Setting.
Standard Features: • NEMA 4, 13. • Weatherproof.
Ambient Temp. Range:-30°F to +160°F or -34°C to +71°C.
Pressure Series: 6860G, 6860GE6862G, 6862GE - Low Range Diaphragm/Instrumentation
Pressure 1.5 H2O to 100 psi.
Model 6860G, 6860GE - Stripped with Single SettingModel 6862G, 6862GE - Stripped with Dual Setting.
Standard Features:•Model 6860GE & 6862GE — Explosion Proof Design to meet the requirements of U.L./CSA Explosion Proof: Division 12 explosion-proof for hazardous locations, Class 1, Groups C,D; Class 2, Groups E, F,G.
• Housed Models — NEMA 4, 13. • Weatherproof.
Ambient Temp. Range:-30°F to +160°F or -34°C to +71°C.
Installation Note:Must be installed with an approved conduit sealbreather to meet the Division 12 requirements.
Pressure Series: 604G, 604P604V - Wide Range DiaphragmPiston
Pressure 0.3 to 4700 psi.Vacuum: 1.0 to 28.5" Hg.
Standard Features:•All models shown are Underwriters’ Laboratories, Inc. listed in the Recognized Components Index, Guide NKPZ "Motor Controllers, FloatPressure Operated," File No. E72038.
• NEMA 4, 13. • Weatherproof. • Internal Case Ground.
Ambient Temp. Range:-30°F to +160°F or -34°C to +71°C.
Pressure Series: 604GZ604GZ-7011 - Wide Range DiaphragmSST Port
Pressure 0.3 to 5000 psi.
Standard Features:•All models shown are Underwriters’ Laboratories, Inc. listed in the Recognized Components Index, Guide NKPZ "Motor Controllers, FloatPressure Operated," File No. E72038.
• NEMA 4, 13. • Weatherproof. • Internal Case Ground. • Fire Resistant Body.
Ambient Temp. Range:-30°F to +160°F or -34°C to +71°C.
Pressure Series: 604D - Low/Mid Range Diaphragm
Differential 0.3 to 75 psid.
Standard Features:•All models shown are Underwriters’ Laboratories, Inc. listed in the Recognized Components Index, Guide NKPZ "Motor Controllers, FloatPressure Operated," File No. E72038.
• NEMA 4, 13. • Weatherproof. • Internal Case Ground.
Ambient Temp. Range:-30°F to +160°F or -34°C to +71°C.
Pressure Series: 646GE, 646PE646VE - Wide Range DiaphragmPiston
Pressure 0.4 to 4700 psiVacuum 1.0 to 28.5" Hg.
Standard Features:•U.L./CSA Explosion Proof: Div. 1, 2 Div. 1 explosion-proofhermetically sealed electrical assembly P/N 17-51 17-73 for "M" model option, listed by both Underwriter’s Laboratories, Inc. File No. E32961CSA Testing Laboratories File No. 22921 for hazardous locations, Class 1, Groups A, B, C,D; Class 2 Groups E, F,G.• NEMA 4, 7, 9, 13.
Ambient Temp. Range:-30°F to +160°F or -34°C to +71°C.
Pressure Series: 646GZE, 646GZE-7011646VZE - Wide Range DiaphragmSST Port
Pressure 0.4 to 4700 psiVacuum 1.0 to 28.5" Hg.
Standard Features:•U.L./CSA Explosion Proof: Div. 1, 2 Div. 1 explosion-proofhermetically sealed electrical assembly P/N 17-51 17-73 for "M" model option, listed by both Underwriter’s Laboratories, Inc. File No. E32961CSA Testing Laboratories File No. 22921 for hazardous locations, Class 1, Groups A, B, C,D; Class 2 Groups E, F,G.• NEMA 4, 7, 9, 13. • Fire Resistant Steel Body.
Ambient Temp. Range:-30°F to +160°F or -34°C to +71°C.
Pressure Series: 646DZE - Low/Mid Range DiaphragmSST Port
Pressure 0.4 to 75 psid.
Standard Features:•U.L./CSA Explosion Proof: Div. 1, 2 Div. 1 explosion-proofhermetically sealed electrical assembly P/N 17-51 17-73 for "M" model option, listed by both Underwriter’s Laboratories, Inc. File No. E32961CSA Testing Laboratories File No. 22921 for hazardous locations, Class 1, Groups A, B, C,D; Class 2 Groups E, F,G.• NEMA 4, 7, 9, 13. • Fire Resistant SST Body.
Ambient Temp. Range:-30°F to +160°F or -34 |
|